M cardiac ultrasound, B Ex Sci, AMS (cardiac), FASE Cardiac sonographer | Educator | Director at Echo Guru Pty Ltd
Joined November 2016
@KemalogluOz Before I get excited about this….i check does the Doppler volume match the MOD and Teicholz SV. And has the true peak gradient been obtained from multiple windows with PEDOF. If all that is consistent data, then consider slow flow as the cause.
0
0
0
@ParrasJorge2 @KemalogluOz I think the most common poorly performed measurement in that equation is LVOT VTI.
0
0
1
@EchoResPract @BSEcho @Kelly_J_Victor @LiamHeartChap @justvick @oxborough77 @Echo_Imaging Great work @Kelly_J_Victor et al! 🫶
0
0
0
Easy to take for granted the challenges we faced transitioning to digital echo. This article brought back a lot of memories of those early days (we were 1st lab in Aust to be fully digital). @ASE360 @VLSorrellImages Video Killed the Radio Star - CASE
1
1
4
RT @LucySafi: 🫀 A deep dive into mitral annular disjunction (MAD) in MVP patients published this month in @JournalASEcho 🔍Pts with MVP wer…
0
51
0
@BeardedHeartDoc @dr_benoy_n_shah @JaeKOh2 @kaznegishi @KemalogluOz @BiancaJudyC I’m assuming they walked to their max and not that the test was terminated because we met an arbitrary 85%… if they walked to fatigue, the RPP was adequate, then I am happy to call it negative without further qualification.
1
0
5
@VLSorrellImages @BiancaJudyC @CASEfromASE @Macquarie_Uni @ASE360 Can't wait to read the editorial for the next issue.... I come for the read, but I stay for the tunes... Here is my playlist from past @VLSorrellImages editorials
0
0
2
RT @josecaferca: Young patient with partial mitral annuloplasty ring detachment 🔪 at @CardioPuerto @ImagenCardiaca @NMerke @alex1708ander @…
0
8
0
@BiancaJudyC @BeardedHeartDoc @Becho2106 @KemalogluOz @sturwohld @RobChamb87 @NMerke @echo_stepbystep @kaznegishi In my experience UEA is excellent for TR. the volume of RBCs is small and enhancement is super useful. In AS though, ALL the RBCs are passing through the EOA, so it’s not an enhancement issue, but a lineup issue. Also high risk of detecting 2nd harmonic artifact in these cases
0
0
0
@BeardedHeartDoc @BiancaJudyC @Becho2106 @KemalogluOz @sturwohld @RobChamb87 @NMerke @echo_stepbystep @kaznegishi I agree with @BeardedHeartDoc that more opening than you appreciate. The high gains on the Doppler makes me nervous you are missing the true signal. If the gains need to be this high, you aren’t getting through the opening. I don’t recommend UEAs in these cases though.
1
0
2
RT @ASE360: It is with immense sadness that we announce a dedicated ASE and #ASEFoundation champion, James Kirkpatrick, passed away yesterd…
0
40
0
@NMerke @ShelbyKuttyMD @iamritu @alcantaramonica @ManiVannanheart @alex1708ander @alexsfelixecho Wow. This looks like a great game of “if you could have dinner with 8 people…”.
0
0
3
@dr_benoy_n_shah @DanXAugustine @alexsfelixecho @NMerke @FGraziani_Grace @echo_stepbystep @senguptasp @EACVIPresident @iamritu @HeartDocSharon @ShelbyKuttyMD Feeling some serious FOMO down here today!!!
0
0
5