![Dr Sarita Rao Profile](https://pbs.twimg.com/profile_images/1296392417046716416/ec1jhvVh_x96.jpg)
Dr Sarita Rao
@DrSaritaRao2
Followers
3K
Following
5K
Statuses
2K
MD,DM,FACC,FESC ,FSCAI Senior consultant interventional cardiologist Apollo hospital Indore PRESIDENT WINCARS Association CO CHAIR EAPCI International Affairs
Indore, India
Joined August 2020
@ABaliMD @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc It's Important to use according to the case. In this case IVL would not cross and MC could not cross so we couldn't get the rota wire in. Always a space for all therapy on our cathlab shelves. Great Inputs from you.
0
0
3
@dhananj25151544 @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Imaging was done once orbital created a space for the catheter to pass. And yes small vessels will perf with higher speeds.
1
0
1
@mirvatalasnag @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Imaging and balloon both failed to cross.
0
0
0
@ABaliMD @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc This is exactly how we used to do nodules earlier. Now we use orbital at 80 ,000 f/b 120,000 and the job is done. Single device only.
1
0
2
@mark_ginkel @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc I have had a great experience with orbital in these cases. You can use the viper wire which can be used even without a MC and use 80,000 f/b 120,000 to modify superficial and deep calcium both. Single device to do the job. This was the result of orbital
0
0
1
@dhananj25151544 @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Excellent approach. This is exactly what we did . Upfront orbital was used with great results. The orbital wire can be used without a MC and orbital can deal with the nodule well. We used initial 80,000 then 120,000 speed and modified superficial and deep calcium as well.
2
0
1
@Ramku14 @nadig_cardio @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc 1.0 balloon did not cross, neither did a MC
0
0
0
@nadig_cardio @Ramku14 @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Excellent thoughts but If a MC does not cross how do u get the rota wire in. Direct wiring with the Rota wire gives us a lot of trouble in such cases
2
0
1
@drShaileshSingh @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Exactly my thought but how about using only one device the orbital?
0
0
0
@KHERA_MD @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Exactly I would probably need Rota and IVL both. So how about only 1 device orbital only?
1
0
0
@nadig_cardio @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc In a calcific nodule why not orbital?
1
0
3
@DrWhyWho @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Rota on a nodule with superficial and deep calcium both?
1
0
0
@DrWhyWho @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Balloon uncrossable so IVL can't be used
1
0
0
@jl35wilsonMD @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc Do u have a good experience with ROTA in a nodule?
1
0
1
@KhurramLiaqat4 @mmamas1973 @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc You can only burr the superficial part of nodule , that too with a favourable wire bias
0
0
0
@stefan_harb @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @ShrillaB @evandrofilhobr @ziadalinyc Balloon uncrossable
1
0
0
@Pardhu6627 @PCRonline @WomenAs1 @IJCDW_WINCARS @APSIC6 @Hragy @GoranEBC @mmamas1973 @mirvatalasnag @drsonyaburgess @crfheart @stefan_harb @ShrillaB @evandrofilhobr @ziadalinyc It would typically shave off the superficial calcium. What about the deep calcium in the nodule
1
0
0
Wonderful session on LM Bifurcation and DCB role in ISR at WINCARS INTERVENTIONAL MEETING yesterday. @PCRonline @APSIC6 @IJCDW_WINCARS @WomenAs1 @SCAI @EAPCIPresident @mirvatalasnag @mmamas1973 @Hragy @CSI_HQ #cardiotwitter
1
1
10
Looking foward to fruitful partnerships and collaberations @APSIC6 @PCRonline @mathur_a @DrRajneeshK @CSI_HQ @GoranEBC @mirvatalasnag @GoranEBC @Dr_AshokSeth @IJCDW_WINCARS
In this edition of @EuroInterventio read about the work of the #EAPCI EAPCI focus on the International Affairs & Partnership Committee: an interview with the Chair, Stefan Harb | Eurointervention @stefan_harb @DrSaritaRao2
3
2
13